Three-phase Oxidized Zinc Radiofire Tester
Posted Sep 22, 2022 | Hits: 62
Country:
China
https://www.mktester.com/lightning-arrester-tester/three-phase-oxidized-zinc-radiofire-tester.html
Overview:
This Tester is used to verify the electrical performance of Zinc Oxide Arrester. The instrument is suitable for various kinds of voltage levels zinc oxide arrester de-energized testing or energized testing thus define the risk and inner insulation moisture and valve aging defects.
Technical parameter:
1.Power supply: support external power adapter (12V/2A) or internal battery
2.Measurement range:
1)Leakage Current Range (peak): 0-10mA (extensible)
2)Voltage range: 30-100V(extensible)
3.Accuracy
1)Current: When total current >100μA ± 2% reading ± 1 digit
2)Voltage: When reference voltage >30V ± 2% reading ± 1 digit
3)Wireless: ± 5% reading ± 1 digit
4.Testing parameters
1)Waveform of Total Leakage Current.
2)RMS and Peak Value of Fundamental Wave
3)RMS of Fundamental Component for Resistive Leakage Current and 3 5 7 times RMS
4)Peak Value of Resistive Leakage Current Component: Ir+ and Ir-
5)Capacitive Current Fundamental Wave Phase angle difference of Total Voltage and Total Current
6)PT Voltage RMS
7)Power Consumption of Arrester
Overview:
This Tester is used to verify the electrical performance of Zinc Oxide Arrester. The instrument is suitable for various kinds of voltage levels zinc oxide arrester de-energized testing or energized testing thus define the risk and inner insulation moisture and valve aging defects.
Technical parameter:
1.Power supply: support external power adapter (12V/2A) or internal battery
2.Measurement range:
1)Leakage Current Range (peak): 0-10mA (extensible)
2)Voltage range: 30-100V(extensible)
3.Accuracy
1)Current: When total current >100μA ± 2% reading ± 1 digit
2)Voltage: When reference voltage >30V ± 2% reading ± 1 digit
3)Wireless: ± 5% reading ± 1 digit
4.Testing parameters
1)Waveform of Total Leakage Current.
2)RMS and Peak Value of Fundamental Wave
3)RMS of Fundamental Component for Resistive Leakage Current and 3 5 7 times RMS
4)Peak Value of Resistive Leakage Current Component: Ir+ and Ir-
5)Capacitive Current Fundamental Wave Phase angle difference of Total Voltage and Total Current
6)PT Voltage RMS
7)Power Consumption of Arrester
0 comments on Three-phase Oxidized Zinc Radiofire Tester
Make a Comment
similar ads
USA, NY, New York
Posted Oct 16, 2023 to Everything Else
USA, NY, New York
Posted Oct 16, 2023 to Everything Else
USA, PA, Pennsylvania
Posted Oct 16, 2023 to Health & Beauty
USA, Louisiana
Posted Oct 16, 2023 to Everything Else
USA, CT
Posted Oct 16, 2023 to Health & Beauty