Ground Network Earth Resistance Tester
Posted Aug 16, 2022 | Hits: 34
Country:
China
https://www.mktester.com/ground-resistance-tester/ground-network-earth-resistance-tester.htmlOverview:
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. Ω measurable substation ground network (4) water and fire power plants microwave station Ω (10) the lightning rod (10 Ω) multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Technical parameter:
measurement range 0~200Ω(including the current pile impedance)
resolution 0.001Ω
measurement error ±(readings×1%+0.005Ω)
maximum output voltage AC 400V (45Hz 55Hz dual-frequency sine wave)
maximum output current AC 5A(45Hz 55Hz dual-frequency sine wave)
Output gear 5 / 4.5/4/3.5/3/2.5/2/1.5/1a every 0.5A 9 gears in total
anti-interference ability anti-power frequency 50Hz voltage 10V
measurement line requirements Section area of copper core of current wire ≥ 1.5mm2
Sectional area of copper core of voltage line ≥ 1.0mm2
power supply AC220V±10%,50Hz
External dimension 295×340×310mm3
instrument weight 30kg
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time.
Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost.
Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. Ω measurable substation ground network (4) water and fire power plants microwave station Ω (10) the lightning rod (10 Ω) multi-purpose machines.
Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Technical parameter:
measurement range 0~200Ω(including the current pile impedance)
resolution 0.001Ω
measurement error ±(readings×1%+0.005Ω)
maximum output voltage AC 400V (45Hz 55Hz dual-frequency sine wave)
maximum output current AC 5A(45Hz 55Hz dual-frequency sine wave)
Output gear 5 / 4.5/4/3.5/3/2.5/2/1.5/1a every 0.5A 9 gears in total
anti-interference ability anti-power frequency 50Hz voltage 10V
measurement line requirements Section area of copper core of current wire ≥ 1.5mm2
Sectional area of copper core of voltage line ≥ 1.0mm2
power supply AC220V±10%,50Hz
External dimension 295×340×310mm3
instrument weight 30kg
0 comments on Ground Network Earth Resistance Tester
Make a Comment
similar ads
India, New Delhi
Posted Dec 23, 2022 to Financial
Posted Dec 23, 2022 to Health & Beauty
https://www.outlookindia.com/outlook-spotlight/let-s-keto-gummies-south-africa-za-is-it-fake-or-t...
New york
Posted Dec 23, 2022 to Health & Beauty
USA, Myrtle Beach
Posted Dec 23, 2022 to Agents & Services
India, Hyderabad
Posted Dec 23, 2022 to Lessons